Set up your own cloud-native simulation in minutes.Start Simulating Now
FEM analyses performed: 1. Static structural — pull-in voltage vs. gap height, confirming Vpi = 4.7 V at t = 2 μm 2. Modal analysis — first 6 resonant modes (5056 Hz to 154,610 Hz) 3. Electromagnetic — S-parameters 25–40 GHz (HFSS/CST) verifying −0.42 dB inser- tion loss and −60 dB isolation at 33 GHz