Steady-state 3D heat conduction of a wall-to-raised-floor junction on a concrete footing. Three wall build-ups: mineral wool timber frame, hempcrete core with wood fibre board, hempcrete core with cork board. Slice 600 mm wide (one stud, one joist). Goal: linear thermal transmittance psi and minimum interior surface temperature (fRsi).
angelpetkov95 created this project
18 days ago
Steady-state 3D heat conduction of a wall-to-raised-floor junction on a concrete footing. Three wall build-ups: mineral wool timber frame, hempcrete core with wood fibre board, hempcrete core with cork board. Slice 600 mm wide (one stud, one joist). Goal: linear thermal transmittance psi and minimum interior surface temperature (fRsi).