Set up your own cloud-native simulation in minutes.Start Simulating Now
Isolated air-passage resistance study. Initial steady laminar incompressible-air numerical smoke test at an assumed 0.5 L/s, density 1.225 kg/m3 and dynamic viscosity 1.81e-5 Pa s. Includes matched inlet and outlet extensions. No fan, heat load, or physical operating-performance claim.
thejobsitein created this project
14 days ago
Isolated air-passage resistance study. Initial steady laminar incompressible-air numerical smoke test at an assumed 0.5 L/s, density 1.225 kg/m3 and dynamic viscosity 1.81e-5 Pa s. Includes matched inlet and outlet extensions. No fan, heat load, or physical operating-performance claim.