Static stiffness verification for an educational hydraulic arm. Reference coupons: 250 mm long, 18 x 18 mm and 18 x 9 mm. Isotropic reference E=10 GPa, Poisson ratio=0.30, gravity off, total end load=1 N. Compare in-plane and lateral bending and check mesh convergence. These assumed properties do not identify the actual timber or establish a safe load rating.
RTSMC created this project
9 days ago
Static stiffness verification for an educational hydraulic arm. Reference coupons: 250 mm long, 18 x 18 mm and 18 x 9 mm. Isotropic reference E=10 GPa, Poisson ratio=0.30, gravity off, total end load=1 N. Compare in-plane and lateral bending and check mesh convergence. These assumed properties do not identify the actual timber or establish a safe load rating.
by Jon_WildeJon_Wilde